HP Proliant - Post Error: 1792 Drive Array Reports Valid Data found in Arary Accelerator

POST Error: 1792-Drive Array Reports Valid Data Found in Array Accelerator... ...Data will automatically be written to drive array.

Possible Cause: Power was interrupted while data was in the array accelerator memory. Power was then restored within several days, and the data in the array accelerator was flushed to the drive array.

Action: No action is required. No data has been lost. Perform orderly system shutdowns to avoid leaving data in the array accelerator.

1792 Error Message Error Message: 1792-Drive Array Reports Valid Data Found in Array Accelerator...

...Data will automatically be written to drive array.
Audible Beeps: None
Possible Cause: Audible Beeps: None Possible Cause:

Power was interrupted while data was in the array accelerator memory. Power was then restored within several days, and the data in the array accelerator was flushed to the drive array.
Action: No action is required. No data has been lost. Perform orderly system shutdowns to avoid leaving data in the array accelerator.